Hydraulický lis

3 Best Questions About Decompression Hydraulic Circuit

3 Best Questions About Decompression Hydraulic Circuit

Předpokládaná doba čtení: 8 minut

Hydraulic Circuit using a pressure-reducing valve Figure 15 allows a cylinder or stroke in the circuit to operate at a low relief valve set pressure. A pressure-reducing valve with a check valve is designed so that when the piston returns, the oil flow passes through the check valve without passing through the pressure-reducing element. Hydraulic Circuit

Hydraulic Circuit
15. Okruh snižování tlaku pomocí redukčního ventilu

1. Návrh okruhu snižujícího tlak, který věnuje pozornost problému

  • Leakage problem of pilot operated pressure reducing Hydraulic Circuit

Be aware of the pilot-operated pressure reducing valve leakage than other control valves. The leakage of this valve can be as much as 1L / min or more. As long as the valve is in working condition, the leakage is always present. In the choice of hydraulic pump capacity, take this into full consideration. It should note that the minimum adjustment pressure of the pressure-reducing valve should ensure that the difference between the primary and the secondary is 0.31MPa. Hydraulic Circuit

  • Problém nestability sekundárního tlaku

The damping hole of the main spool of the pressure reducing valve is blocked so that the oil exported from the pressure reducing valve cannot flow smoothly into the capacitive cavity between the main valve and the pilot valve. And the pilot valve also reduces the control role of the secondary pressure exported from the pressure reducing valve, resulting in unstable secondary pressure. Hydraulic Circuit

2. Decompression Hydraulic Circuit component setting problem

As shown in Figure 16, the pressure in the branch circuit cylinder 2 after the pressure-reducing valve 3 is lower than the fluid pressure in the master cylinder 1 branch circuit, which is called a pressure reducing circuit. The problems of this circuit are as follows. Hydraulic Circuit

  • When cylinder 2 is stopped for a long time, the secondary pressure after pressure reducing valve 3 gradually increases. This is because when cylinder 2 is stopped for a long time, a small amount of oil is discharged through the pilot valve through the spool gap to keep the valve in working condition. Due to the leakage in the valve, the flow through the pilot valve increases, and the secondary pressure (outlet pressure) of the pressure-reducing valve increases. To prevent this failure, you can add the oil circuit shown in the dashed line in the pressure reducing circuit, and install a safety valve at b to ensure that the pressure reducing valve outlet pressure does not exceed its adjustment Hydraulic Circuit.
1-Hlavní válec; 2-Odbočný válec; 3-Redukční ventil; 4-A škrticí klapka
16. 1-hlavní válec; Válec se 2 větvemi; 3-redukční ventil; 4-A škrticí ventil
  • The speed adjustment of the hydraulic cylinder in the pressure reducing circuit is not working or the speed is not stable. As shown in Figure 16, this problem occurs when the leakage of pressure-reducing valve 3 (the fluid flowing back to the tank from the pressure-reducing valve drain port) is large. The solution is to change the throttle valve from the position in the figure to connected in series at an after the pressure reducing valve, to avoid the effect of pressure reducing valve leakage on the speed of cylinder 2. Hydraulic Circuit

3. Nestabilní pracovní tlak okruhu snižujícího tlak

In the system shown in Figure 17, the hydraulic pump is quantitative, and the hydraulic cylinders 7 and 8 in the main oil circuit are controlled by two-position four-way electro-hydraulic reversing valves 5 and 6 respectively to control the direction of motion, and the control fluid of the electro-hydraulic reversing valves comes from main oil Hydraulic Circuit.

Okruh redukčního tlaku je připojen paralelně k hlavnímu olejovému okruhu a je odtlakován redukčním ventilem 3. Dvoupolohový čtyřcestný elektromagnetický ventil ovládá směr pohybu hydraulického válce 9.

The electro-hydraulic reversing valve controls the return line of the oil circuit and the external drain of the pressure reducing valve. The oil circuit merges and return to the tank, and the operating pressure of the system is regulated by the relief valve2. Hydraulic Circuit

The main oil circuit in the system works normally, but in the pressure reducing circuit, the pressure downstream of the pressure reducing valve fluctuates greatly, so that the working pressure of hydraulic cylinder 9 cannot be stabilized at the regulated pressure value of 1MPa. Hydraulic Circuit

Příklad systému s nestabilním tlakem na výstupu redukčního ventilu1 pevné čerpadlo; 2 - pojistný ventil; 3 - redukční ventil; 4 dvoupolohový čtyřcestný solenoidem ovládaný přepínací ventil; 5,6 - dvoupolohový čtyřcestný elektrohydraulický přepínací ventil;7 až 9 - hydraulický válec; 10 - manometr
17. Příklad systému s nestabilním tlakem na výstupu z redukčního ventilu
1 pevné čerpadlo; 2 - přepouštěcí ventil; 3 - redukční ventil; 4 dvoupolohový čtyřcestný elektromagneticky ovládaný reverzní ventil; 5,6-dvoupolohový čtyřcestný elektrohydraulický reverzní ventil;
7 až 9 - hydraulický válec; 10 - tlakoměr

In the pressure reducing circuit, the downstream pressure of the pressure reducing valve, the working pressure of the pressure reducing circuit, occurs in large fluctuations is a frequent failure phenomenon, the main reasons for which are the following. Hydraulic Circuit

  • The prerequisite for a pressure reducing valve to be able to stabilise the pressure downstream of the valve at the regulated value is that the upstream pressure of the pressure reducing valve should be higher than the downstream pressure, otherwise the pressure downstream of the pressure reducing valve cannot be stabilised. Main hydraulic circuit working pressure change significantly. Hydraulic Circuit

It will have a larger impact if the minimum pressure value changes lower than the downstream pressure of the pressure-reducing valve, this is because when the upstream pressure of the pressure reducing valve is increase, the downstream pressure may have to be increase instantaneously, but through the regulating action of the pressure reducing valve it will quickly return to the regulating valve. Conversely, when the upstream pressure of the pressure-reducing valve reduces, the downstream pressure of the pressure-reducing valve should reduce instantaneously, and the pressure-reducing valve will quickly adjust so that the downstream pressure rises to the regulated value. Hydraulic Circuit

Pokud výstupní tlak kolísá a jeho minimální tlak je nižší než fixní hodnota výstupního tlaku, musí být výstupní tlak odpovídajícím způsobem snížen a nemůže se stabilizovat na regulované hodnotě tlaku.

Proto se při změnách zatížení pohonu hlavního olejového okruhu v provozních podmínkách, kdy je minimální pracovní tlak nižší než tlak po proudu, měla konstrukce okruhu přijmout nezbytná opatření, jako je přidání zpětného ventilu, přidání akumulátoru mezi zpětný ventil a redukční ventil atd., aby se zabránilo změnám tlaku před tlakem pod tlakem po proudu.

  • Zatížení pohonu je nestabilní. V redukčním okruhu je výstupní tlak stabilní pouze díky regulačnímu účinku redukčního ventilu. Když má pohon dostatečné zatížení, musí se tlak ve směru proudu řídit objektivním zákonem, tj. Tlak by měl být určen zátěží. Bez zatížení se nemůže vytvářet žádný tlak a při nízkém zatížení je tlak nižší. Pokud je v určitém okamžiku tlakový redukční okruh, tlak za redukčním ventilem nastaven v podmínkách zatížení, ale v pracovním procesu redukčního okruhu, když je zatížení sníženo, měl by výstupní tlak redukčního ventilu snížit až na nulu. Když se zatížení znovu zvýší, zvýší se výstupní tlak redukčního ventilu a když se tlak zvýší se zatížením na regulační tlak redukčního ventilu, tlak se nezvyšuje se zátěží, ale zůstává na regulačním tlaku hodnota redukčního ventilu.

Proto se za podmínek proměnlivého zatížení mění výstupní tlak tlaku redukčního ventilu a tato změna může být pouze nižší než regulační hodnota redukčního ventilu, ale ne vyšší než regulační hodnota.

  • Ve vnějším odtokovém potrubí je protitlak. Ovládací potrubí redukčního ventilu je externí vypouštěcí potrubí. řídicí kapalina tlačí kuželový ventil a poté se vrací zpět do nádrže samostatně. Pokud se u externího vypouštěcího potrubí mění protitlak, přímo to ovlivňuje tlak tlakového oleje tlačící kuželový ventil, což způsobuje změnu tlaku a tím i změnu provozního tlaku za redukčním ventilem.

Poruchový jev v systému zobrazeném na obrázku 17 je analyzován inspekcí a je způsoben změnou protitlaku ve vnějším okruhu odvodňovacího oleje redukčního ventilu.

It is easy to see that the electro-hydraulic reversing valves 5 and 6 in the system is changing in the process of reversing the flow and pressure of the return oil in the control oil circuit. The oil in the external drainage circuit of the pressure-reducing valve is also fluctuating, and the two streams of oil merge to produce unstable backpressure.

After debugging, when the electro-hydraulic reversing valves 5 and 6 act at the same time, the pressure gauge 10 reads 1.5 MPa. This is because the electro-hydraulic reversing valve is under the action of a high-pressure control fluid, the instantaneous flow is larger, and in the case of a longer drain pipe, higher backpressure is generated, the backpressure increases. So that the main valve opening of the pressure reducing valve increases, and the local pressure at the valve opening decreases, so the working pressure of the pressure reducing valve increases.

Aby se odstranila tato chyba, vypouštěcí potrubí redukčního ventilu a elektrohydraulický reverzní ventil 5 a 6 by měly být připojeny zpět k olejové nádrži samostatně, aby vypouštěcí potrubí redukčního ventilu mohlo proudit zpět do olejové nádrže stabilně bez rušení a kolísání a výstupní tlak bude stabilní při regulované hodnotě tlaku.

Tato výše uvedená analýza ukazuje, že během návrhu a instalace systému bychom při porozumění pracovnímu výkonu komponent měli pečlivě zvážit, zda se tyto komponenty navzájem ruší.

1 myšlenky na „3 Best Questions About Decompression Hydraulic Circuit

  1. Avatar Simon Simon napsal:

    Dobrý den, máte jediný hydraulický lis, díky?

Napsat komentář

Vaše e-mailová adresa nebude zveřejněna. Vyžadované informace jsou označeny *