Hydraulic Circuit using a pressure-reducing valve Figure 15 allows a cylinder or stroke in the circuit to operate at a low relief valve set pressure. A pressure-reducing valve with a check valve is designed so that when the piston returns, the oil flow passes through the check valve without passing through the pressure-reducing element. Hydraulic Circuit

Hydraulic Circuit
15. Mạch giảm áp sử dụng van giảm áp

1. Việc thiết kế mạch giảm áp cần lưu ý vấn đề gì

  • Leakage problem of pilot operated pressure reducing Hydraulic Circuit

Be aware of the pilot-operated pressure reducing valve leakage than other control valves. The leakage of this valve can be as much as 1L / min or more. As long as the valve is in working condition, the leakage is always present. In the choice of hydraulic pump capacity, take this into full consideration. It should note that the minimum adjustment pressure of the pressure-reducing valve should ensure that the difference between the primary and the secondary is 0.31MPa. Hydraulic Circuit

  • Vấn đề mất ổn định áp suất thứ cấp

The damping hole of the main spool of the pressure reducing valve is blocked so that the oil exported from the pressure reducing valve cannot flow smoothly into the capacitive cavity between the main valve and the pilot valve. And the pilot valve also reduces the control role of the secondary pressure exported from the pressure reducing valve, resulting in unstable secondary pressure. Hydraulic Circuit

2. Decompression Hydraulic Circuit component setting problem

As shown in Figure 16, the pressure in the branch circuit cylinder 2 after the pressure-reducing valve 3 is lower than the fluid pressure in the master cylinder 1 branch circuit, which is called a pressure reducing circuit. The problems of this circuit are as follows. Hydraulic Circuit

  • When cylinder 2 is stopped for a long time, the secondary pressure after pressure reducing valve 3 gradually increases. This is because when cylinder 2 is stopped for a long time, a small amount of oil is discharged through the pilot valve through the spool gap to keep the valve in working condition. Due to the leakage in the valve, the flow through the pilot valve increases, and the secondary pressure (outlet pressure) of the pressure-reducing valve increases. To prevent this failure, you can add the oil circuit shown in the dashed line in the pressure reducing circuit, and install a safety valve at b to ensure that the pressure reducing valve outlet pressure does not exceed its adjustment Hydraulic Circuit.
1-Master cylinder; 2-Branch cylinder; 3-Reducing valve; 4-A throttle valve
16. 1-Xi lanh chủ; 2-Nhánh xi lanh; 3-Van giảm tốc; Van tiết lưu 4-A
  • The speed adjustment of the hydraulic cylinder in the pressure reducing circuit is not working or the speed is not stable. As shown in Figure 16, this problem occurs when the leakage of pressure-reducing valve 3 (the fluid flowing back to the tank from the pressure-reducing valve drain port) is large. The solution is to change the throttle valve from the position in the figure to connected in series at an after the pressure reducing valve, to avoid the effect of pressure reducing valve leakage on the speed of cylinder 2. Hydraulic Circuit

3. Áp suất làm việc không ổn định của mạch giảm áp

In the system shown in Figure 17, the hydraulic pump is quantitative, and the hydraulic cylinders 7 and 8 in the main oil circuit are controlled by two-position four-way electro-hydraulic reversing valves 5 and 6 respectively to control the direction of motion, and the control fluid of the electro-hydraulic reversing valves comes from main oil Hydraulic Circuit.

Mạch giảm áp được nối song song với mạch dầu chính và được khử áp bằng van giảm áp 3. Van điện từ hai vị trí bốn chiều điều khiển hướng chuyển động của xi lanh thủy lực 9.

The electro-hydraulic reversing valve controls the return line of the oil circuit and the external drain of the pressure reducing valve. The oil circuit merges and return to the tank, and the operating pressure of the system is regulated by the relief valve2. Hydraulic Circuit

The main oil circuit in the system works normally, but in the pressure reducing circuit, the pressure downstream of the pressure reducing valve fluctuates greatly, so that the working pressure of hydraulic cylinder 9 cannot be stabilized at the regulated pressure value of 1MPa. Hydraulic Circuit

Example of a system with unstable pressure at the outlet of a pressure reducing valve1 fixed pump; 2 - relief valve; 3 - pressure reducing valve; 4 a two-position four-way solenoid-operated reversing valve; 5,6 - two-position four-way electro-hydraulic reversing valve;7 to 9 - hydraulic cylinder; 10 - pressure gauge
17. Ví dụ về hệ thống có áp suất không ổn định ở đầu ra của van giảm áp
1 máy bơm cố định; 2 - van xả; 3 - van giảm áp; 4 van đảo chiều hoạt động bằng điện từ hai vị trí bốn chiều; 5,6 - van đảo chiều điện thủy lực hai vị trí bốn chiều;
7 đến 9 - xi lanh thủy lực; 10 - đồng hồ áp suất

In the pressure reducing circuit, the downstream pressure of the pressure reducing valve, the working pressure of the pressure reducing circuit, occurs in large fluctuations is a frequent failure phenomenon, the main reasons for which are the following. Hydraulic Circuit

  • The prerequisite for a pressure reducing valve to be able to stabilise the pressure downstream of the valve at the regulated value is that the upstream pressure of the pressure reducing valve should be higher than the downstream pressure, otherwise the pressure downstream of the pressure reducing valve cannot be stabilised. Main hydraulic circuit working pressure change significantly. Hydraulic Circuit

It will have a larger impact if the minimum pressure value changes lower than the downstream pressure of the pressure-reducing valve, this is because when the upstream pressure of the pressure reducing valve is increase, the downstream pressure may have to be increase instantaneously, but through the regulating action of the pressure reducing valve it will quickly return to the regulating valve. Conversely, when the upstream pressure of the pressure-reducing valve reduces, the downstream pressure of the pressure-reducing valve should reduce instantaneously, and the pressure-reducing valve will quickly adjust so that the downstream pressure rises to the regulated value. Hydraulic Circuit

Nếu áp suất thượng nguồn dao động và áp suất tối thiểu của nó thấp hơn giá trị cố định của áp suất hạ lưu thì áp suất hạ lưu phải giảm tương ứng và không thể ổn định ở giá trị áp suất quy định.

Do đó, trong điều kiện hoạt động của bộ truyền động dầu chính tải thay đổi, khi áp suất làm việc tối thiểu thấp hơn áp suất hạ lưu, thiết kế mạch cần thực hiện các biện pháp cần thiết, chẳng hạn như thêm một van một chiều, thêm một bộ tích lũy giữa van một chiều và van giảm áp, v.v., để ngăn chặn sự thay đổi áp suất ở thượng nguồn thấp hơn áp suất ở hạ lưu.

  • Tải trên cơ cấu chấp hành không ổn định. Trong mạch giảm áp, hạ áp chỉ ổn định do tác dụng điều tiết của van giảm áp. Với cơ cấu chấp hành đã đủ tải, áp suất hạ nguồn vẫn phải tuân theo quy luật khách quan, đó là áp suất phải do tải quyết định. Không có áp suất nào có thể hình thành khi không có tải, và áp suất sẽ thấp hơn khi có tải thấp. Nếu mạch giảm áp thì áp suất sau van giảm áp đặt ở điều kiện có tải tại một thời điểm nhất định, nhưng trong quá trình làm việc của mạch giảm áp, khi giảm tải thì áp suất sau van giảm áp nên giảm cho đến khi bằng không. Khi tăng tải trở lại thì áp suất hạ lưu của van giảm áp tăng, khi tăng áp theo tải lên áp suất điều hòa của van giảm áp thì áp suất không tăng theo tải mà vẫn ở áp suất điều hòa. giá trị của van giảm áp.

Do đó, trong điều kiện tải thay đổi, giá trị áp suất hạ lưu của van giảm áp thay đổi, và sự biến đổi này chỉ có thể thấp hơn giá trị điều chỉnh của van giảm áp, nhưng không cao hơn giá trị điều chỉnh.

  • Có áp lực ngược trong đường thoát nước bên ngoài. Đường điều khiển của van giảm áp là đường xả bên ngoài. chất lỏng điều khiển đẩy van hình nón mở và sau đó trở lại bể chứa riêng biệt. Nếu đường xả bên ngoài có áp suất ngược thay đổi, nó ảnh hưởng trực tiếp đến áp suất của dầu có áp suất đẩy van côn, gây ra sự thay đổi áp suất và do đó làm thay đổi áp suất vận hành hạ lưu của van giảm áp.

Hiện tượng sự cố trong hệ thống thể hiện trong Hình 17 được phân tích khi kiểm tra và gây ra bởi sự thay đổi áp suất ngược trong mạch dầu thoát nước bên ngoài của van giảm áp.

It is easy to see that the electro-hydraulic reversing valves 5 and 6 in the system is changing in the process of reversing the flow and pressure of the return oil in the control oil circuit. The oil in the external drainage circuit of the pressure-reducing valve is also fluctuating, and the two streams of oil merge to produce unstable backpressure.

After debugging, when the electro-hydraulic reversing valves 5 and 6 act at the same time, the pressure gauge 10 reads 1.5 MPa. This is because the electro-hydraulic reversing valve is under the action of a high-pressure control fluid, the instantaneous flow is larger, and in the case of a longer drain pipe, higher backpressure is generated, the backpressure increases. So that the main valve opening of the pressure reducing valve increases, and the local pressure at the valve opening decreases, so the working pressure of the pressure reducing valve increases.

Để loại bỏ lỗi này, đường xả của van giảm áp và van đảo chiều điện-thủy lực 5 và 6 phải được kết nối trở lại thùng dầu riêng biệt, để đường xả của van giảm áp có thể chảy trở lại thùng dầu một cách ổn định mà không bị nhiễu và dao động, và áp suất hạ lưu sẽ ổn định ở giá trị áp suất quy định.

Phân tích trên cho thấy trong quá trình thiết kế và lắp đặt hệ thống, trong khi tìm hiểu hiệu suất làm việc của các thành phần, chúng ta nên xem xét kỹ các thành phần có gây nhiễu lẫn nhau hay không.