Hydraulic Circuit using a pressure-reducing valve Figure 15 allows a cylinder or stroke in the circuit to operate at a low relief valve set pressure. A pressure-reducing valve with a check valve is designed so that when the piston returns, the oil flow passes through the check valve without passing through the pressure-reducing element. Hydraulic Circuit
1. تصميم دائرة تخفيض الضغط للاهتمام بالمشكلة
- Leakage problem of pilot operated pressure reducing Hydraulic Circuit
Be aware of the pilot-operated pressure reducing valve leakage than other control valves. The leakage of this valve can be as much as 1L / min or more. As long as the valve is in working condition, the leakage is always present. In the choice of hydraulic pump capacity, take this into full consideration. It should note that the minimum adjustment pressure of the pressure-reducing valve should ensure that the difference between the primary and the secondary is 0.31MPa. Hydraulic Circuit
- مشكلة عدم استقرار الضغط الثانوي
The damping hole of the main spool of the pressure reducing valve is blocked so that the oil exported from the pressure reducing valve cannot flow smoothly into the capacitive cavity between the main valve and the pilot valve. And the pilot valve also reduces the control role of the secondary pressure exported from the pressure reducing valve, resulting in unstable secondary pressure. Hydraulic Circuit
2. Decompression Hydraulic Circuit component setting problem
As shown in Figure 16, the pressure in the branch circuit cylinder 2 after the pressure-reducing valve 3 is lower than the fluid pressure in the master cylinder 1 branch circuit, which is called a pressure reducing circuit. The problems of this circuit are as follows. Hydraulic Circuit
- When cylinder 2 is stopped for a long time, the secondary pressure after pressure reducing valve 3 gradually increases. This is because when cylinder 2 is stopped for a long time, a small amount of oil is discharged through the pilot valve through the spool gap to keep the valve in working condition. Due to the leakage in the valve, the flow through the pilot valve increases, and the secondary pressure (outlet pressure) of the pressure-reducing valve increases. To prevent this failure, you can add the oil circuit shown in the dashed line in the pressure reducing circuit, and install a safety valve at b to ensure that the pressure reducing valve outlet pressure does not exceed its adjustment Hydraulic Circuit.
- The speed adjustment of the hydraulic cylinder in the pressure reducing circuit is not working or the speed is not stable. As shown in Figure 16, this problem occurs when the leakage of pressure-reducing valve 3 (the fluid flowing back to the tank from the pressure-reducing valve drain port) is large. The solution is to change the throttle valve from the position in the figure to connected in series at an after the pressure reducing valve, to avoid the effect of pressure reducing valve leakage on the speed of cylinder 2. Hydraulic Circuit
3. ضغط العمل غير المستقر لدائرة تخفيض الضغط
In the system shown in Figure 17, the hydraulic pump is quantitative, and the hydraulic cylinders 7 and 8 in the main oil circuit are controlled by two-position four-way electro-hydraulic reversing valves 5 and 6 respectively to control the direction of motion, and the control fluid of the electro-hydraulic reversing valves comes from main oil Hydraulic Circuit.
يتم توصيل دائرة تخفيض الضغط بالتوازي مع دائرة الزيت الرئيسية ويتم تخفيف الضغط عن طريق صمام تخفيض الضغط 3. يتحكم صمام الملف اللولبي ثنائي الوضع رباعي الاتجاهات في اتجاه حركة الأسطوانة الهيدروليكية 9.
The electro-hydraulic reversing valve controls the return line of the oil circuit and the external drain of the pressure reducing valve. The oil circuit merges and return to the tank, and the operating pressure of the system is regulated by the relief valve2. Hydraulic Circuit
The main oil circuit in the system works normally, but in the pressure reducing circuit, the pressure downstream of the pressure reducing valve fluctuates greatly, so that the working pressure of hydraulic cylinder 9 cannot be stabilized at the regulated pressure value of 1MPa. Hydraulic Circuit
In the pressure reducing circuit, the downstream pressure of the pressure reducing valve, the working pressure of the pressure reducing circuit, occurs in large fluctuations is a frequent failure phenomenon, the main reasons for which are the following. Hydraulic Circuit
- The prerequisite for a pressure reducing valve to be able to stabilise the pressure downstream of the valve at the regulated value is that the upstream pressure of the pressure reducing valve should be higher than the downstream pressure, otherwise the pressure downstream of the pressure reducing valve cannot be stabilised. Main hydraulic circuit working pressure change significantly. Hydraulic Circuit
It will have a larger impact if the minimum pressure value changes lower than the downstream pressure of the pressure-reducing valve, this is because when the upstream pressure of the pressure reducing valve is increase, the downstream pressure may have to be increase instantaneously, but through the regulating action of the pressure reducing valve it will quickly return to the regulating valve. Conversely, when the upstream pressure of the pressure-reducing valve reduces, the downstream pressure of the pressure-reducing valve should reduce instantaneously, and the pressure-reducing valve will quickly adjust so that the downstream pressure rises to the regulated value. Hydraulic Circuit
إذا تذبذب ضغط المنبع وكان ضغطه الأدنى أقل من القيمة الثابتة لضغط المصب ، فيجب تقليل ضغط المصب وفقًا لذلك ولا يمكن أن يستقر عند قيمة الضغط المنظمة.
لذلك ، يتغير حمل المحرك الرئيسي لدائرة الزيت في ظروف التشغيل ، عندما يكون ضغط العمل الأدنى أقل من الضغط في اتجاه التيار ، يجب أن يتخذ تصميم الدائرة التدابير اللازمة ، مثل إضافة صمام فحص ، وإضافة مجمع بين فحص الصمام وصمام تخفيض الضغط ، وما إلى ذلك ، من أجل منع تغيرات الضغط في المنبع أسفل الضغط في اتجاه التيار.
- الحمل على المشغل غير مستقر. في دائرة تخفيض الضغط ، يكون ضغط المصب مستقرًا فقط بسبب التأثير التنظيمي لصمام تخفيض الضغط. مع وجود حمولة كافية للمشغل ، لا يزال يتعين على ضغط المصب اتباع القانون الموضوعي ، أي الضغط يجب أن يتم تحديده بواسطة الحمل. لا يمكن أن يتشكل ضغط بدون حمل ، ويكون الضغط أقل مع حمولة منخفضة. إذا كانت دائرة تخفيض الضغط ، فإن الضغط بعد صمام تخفيض الضغط يتم ضبطه في حالة الحمل في لحظة معينة ، ولكن في عملية تشغيل دائرة تخفيض الضغط ، عندما يتم تقليل الحمل ، يجب أن يكون ضغط التيار لصمام تخفيض الضغط خفض حتى الصفر. عندما يزداد الحمل مرة أخرى ، يزداد ضغط مجرى النهر لصمام تخفيض الضغط ، وعندما يزداد الضغط مع الحمل إلى الضغط المنظم لصمام تخفيض الضغط ، لا يزداد الضغط مع الحمل ولكنه يظل عند الضغط المنظم قيمة صمام تخفيض الضغط.
لذلك ، في ظل ظروف الحمل المتغيرة ، تختلف قيمة ضغط المصب لصمام تخفيض الضغط ، ويمكن أن يكون هذا الاختلاف أقل فقط من القيمة المنظمة لصمام تخفيض الضغط ، ولكن ليس أعلى من القيمة المنظمة.
- يوجد ضغط عكسي في خط الصرف الخارجي. خط التحكم في صمام تخفيض الضغط هو خط تصريف خارجي. يقوم سائل التحكم بدفع الصمام المخروطي مفتوحًا ثم يعود إلى الخزان بشكل منفصل. إذا تم تغيير ضغط عكسي لخط الصرف الخارجي ، فإنه يؤثر بشكل مباشر على ضغط زيت الضغط الذي يدفع الصمام المخروطي ، مما يتسبب في حدوث تغيير في الضغط وبالتالي تغيير في ضغط التشغيل السفلي لصمام تقليل الضغط.
يتم تحليل ظاهرة العطل في النظام الموضح في الشكل 17 عن طريق الفحص وينتج عن تغيير في الضغط الخلفي في دائرة زيت الصرف الخارجي لصمام تخفيض الضغط.
It is easy to see that the electro-hydraulic reversing valves 5 and 6 in the system is changing in the process of reversing the flow and pressure of the return oil in the control oil circuit. The oil in the external drainage circuit of the pressure-reducing valve is also fluctuating, and the two streams of oil merge to produce unstable backpressure.
After debugging, when the electro-hydraulic reversing valves 5 and 6 act at the same time, the pressure gauge 10 reads 1.5 MPa. This is because the electro-hydraulic reversing valve is under the action of a high-pressure control fluid, the instantaneous flow is larger, and in the case of a longer drain pipe, higher backpressure is generated, the backpressure increases. So that the main valve opening of the pressure reducing valve increases, and the local pressure at the valve opening decreases, so the working pressure of the pressure reducing valve increases.
للتخلص من هذا الخطأ ، يجب توصيل خط تصريف صمام تخفيض الضغط وصمام الانعكاس الكهروهيدروليكي 5 و 6 مرة أخرى بخزان الزيت بشكل منفصل ، بحيث يمكن لخط تصريف صمام تخفيض الضغط أن يتدفق مرة أخرى إلى خزان الزيت بثبات دون تدخل و التقلب ، وضغط المصب سيكون مستقرًا عند قيمة الضغط المنظمة.
يوضح هذا التحليل أعلاه أنه أثناء تصميم النظام وتثبيته ، أثناء فهم أداء عمل المكونات ، يجب أن نفكر جيدًا فيما إذا كانت المكونات ستتداخل مع بعضها البعض.