3 Best Questions About Decompression Hydraulic Circuit

3 Best Questions About Decompression Hydraulic Circuit

Geschätzte Lesezeit: 8 Protokoll

Hydraulic Circuit using a pressure-reducing valve Figure 15 allows a cylinder or stroke in the circuit to operate at a low relief valve set pressure. A pressure-reducing valve with a check valve is designed so that when the piston returns, the oil flow passes through the check valve without passing through the pressure-reducing element. Hydraulic Circuit

Hydraulic Circuit
15. Druckreduzierkreis mit Druckreduzierventil

1. Das Design des Druckreduzierkreises, um das Problem zu berücksichtigen

  • Leakage problem of pilot operated pressure reducing Hydraulic Circuit

Be aware of the pilot-operated pressure reducing valve leakage than other control valves. The leakage of this valve can be as much as 1L / min or more. As long as the valve is in working condition, the leakage is always present. In the choice of hydraulic pump capacity, take this into full consideration. It should note that the minimum adjustment pressure of the pressure-reducing valve should ensure that the difference between the primary and the secondary is 0.31MPa. Hydraulic Circuit

  • Sekundärdruckinstabilitätsproblem

The damping hole of the main spool of the pressure reducing valve is blocked so that the oil exported from the pressure reducing valve cannot flow smoothly into the capacitive cavity between the main valve and the pilot valve. And the pilot valve also reduces the control role of the secondary pressure exported from the pressure reducing valve, resulting in unstable secondary pressure. Hydraulic Circuit

2. Decompression Hydraulic Circuit component setting problem

As shown in Figure 16, the pressure in the branch circuit cylinder 2 after the pressure-reducing valve 3 is lower than the fluid pressure in the master cylinder 1 branch circuit, which is called a pressure reducing circuit. The problems of this circuit are as follows. Hydraulic Circuit

  • When cylinder 2 is stopped for a long time, the secondary pressure after pressure reducing valve 3 gradually increases. This is because when cylinder 2 is stopped for a long time, a small amount of oil is discharged through the pilot valve through the spool gap to keep the valve in working condition. Due to the leakage in the valve, the flow through the pilot valve increases, and the secondary pressure (outlet pressure) of the pressure-reducing valve increases. To prevent this failure, you can add the oil circuit shown in the dashed line in the pressure reducing circuit, and install a safety valve at b to ensure that the pressure reducing valve outlet pressure does not exceed its adjustment Hydraulic Circuit.
1-Master cylinder; 2-Branch cylinder; 3-Reducing valve; 4-A throttle valve
16. 1-Hauptzylinder; 2-Zweig-Zylinder; 3-Reduzierventil; 4-A Drosselklappe
  • The speed adjustment of the hydraulic cylinder in the pressure reducing circuit is not working or the speed is not stable. As shown in Figure 16, this problem occurs when the leakage of pressure-reducing valve 3 (the fluid flowing back to the tank from the pressure-reducing valve drain port) is large. The solution is to change the throttle valve from the position in the figure to connected in series at an after the pressure reducing valve, to avoid the effect of pressure reducing valve leakage on the speed of cylinder 2. Hydraulic Circuit

3. Instabiler Arbeitsdruck des Druckreduzierkreises

In the system shown in Figure 17, the hydraulic pump is quantitative, and the hydraulic cylinders 7 and 8 in the main oil circuit are controlled by two-position four-way electro-hydraulic reversing valves 5 and 6 respectively to control the direction of motion, and the control fluid of the electro-hydraulic reversing valves comes from main oil Hydraulic Circuit.

Der Druckminderkreis ist parallel zum Hauptölkreis geschaltet und wird durch das Druckminderventil 3 drucklos gemacht. Das Zweistellungs-Vierwege-Magnetventil steuert die Bewegungsrichtung des Hydraulikzylinders 9.

The electro-hydraulic reversing valve controls the return line of the oil circuit and the external drain of the pressure reducing valve. The oil circuit merges and return to the tank, and the operating pressure of the system is regulated by the relief valve2. Hydraulic Circuit

The main oil circuit in the system works normally, but in the pressure reducing circuit, the pressure downstream of the pressure reducing valve fluctuates greatly, so that the working pressure of hydraulic cylinder 9 cannot be stabilized at the regulated pressure value of 1MPa. Hydraulic Circuit

Example of a system with unstable pressure at the outlet of a pressure reducing valve1 fixed pump; 2 - relief valve; 3 - pressure reducing valve; 4 a two-position four-way solenoid-operated reversing valve; 5,6 - two-position four-way electro-hydraulic reversing valve;7 to 9 - hydraulic cylinder; 10 - pressure gauge
17. Beispiel für ein System mit instabilem Druck am Ausgang eines Druckminderventils
1 feste Pumpe; 2 – Entlastungsventil; 3 – Druckminderer; 4 ein magnetbetätigtes Vierwege-Umschaltventil mit zwei Stellungen; 5,6 – elektrohydraulisches 4-Wege-Umschaltventil mit zwei Positionen;
7 bis 9 – Hydraulikzylinder; 10 – Manometer

In the pressure reducing circuit, the downstream pressure of the pressure reducing valve, the working pressure of the pressure reducing circuit, occurs in large fluctuations is a frequent failure phenomenon, the main reasons for which are the following. Hydraulic Circuit

  • The prerequisite for a pressure reducing valve to be able to stabilise the pressure downstream of the valve at the regulated value is that the upstream pressure of the pressure reducing valve should be higher than the downstream pressure, otherwise the pressure downstream of the pressure reducing valve cannot be stabilised. Main hydraulic circuit working pressure change significantly. Hydraulic Circuit

It will have a larger impact if the minimum pressure value changes lower than the downstream pressure of the pressure-reducing valve, this is because when the upstream pressure of the pressure reducing valve is increase, the downstream pressure may have to be increase instantaneously, but through the regulating action of the pressure reducing valve it will quickly return to the regulating valve. Conversely, when the upstream pressure of the pressure-reducing valve reduces, the downstream pressure of the pressure-reducing valve should reduce instantaneously, and the pressure-reducing valve will quickly adjust so that the downstream pressure rises to the regulated value. Hydraulic Circuit

Wenn der Vordruck schwankt und sein Mindestdruck kleiner als der feste Wert des Nachdrucks ist, muss der Nachdruck entsprechend reduziert werden und kann sich nicht auf den geregelten Druckwert stabilisieren.

Daher sollte die Auslegung des Kreislaufs die erforderlichen Maßnahmen ergreifen, wie z Rückschlagventil und Druckminderer usw., um zu verhindern, dass sich der Druck vor dem Druck unter den Druck nach unten ändert.

  • Die Belastung des Aktuators ist instabil. Im Druckreduzierkreis ist der Hinterdruck nur durch die Regelwirkung des Druckreduzierventils stabil. Bei ausreichender Last des Aktors muss der Hinterdruck immer noch dem objektiven Gesetz folgen, dh der Druck sollte durch die Last bestimmt werden. Ohne Last kann sich kein Druck bilden und bei geringer Last ist der Druck geringer. Wenn der Druckreduzierkreis, der Druck nach dem Druckreduzierventil zu einem bestimmten Zeitpunkt unter Lastbedingung eingestellt ist, aber im Arbeitsprozess des Druckreduzierkreises, wenn die Last reduziert wird, sollte der Hinterdruck des Druckreduzierventils auf Null reduzieren. Steigt die Last wieder an, steigt der Hinterdruck des Druckminderers, und steigt der Druck mit der Last auf den Regeldruck des Druckminderers an, steigt der Druck nicht mit der Last, sondern bleibt auf dem Regeldruck Wert des Druckminderventils.

Daher variiert unter variablen Lastbedingungen der stromabwärtige Druckwert des Druckreduzierventils, und diese Variation kann nur niedriger als der Regelwert des Druckreduzierventils sein, aber nicht höher als der Regelwert.

  • In der externen Ablaufleitung herrscht Gegendruck. Die Steuerleitung des Druckminderers ist eine externe Ablaufleitung. die Steuerflüssigkeit drückt das Kegelventil auf und kehrt dann separat in den Tank zurück. Wenn sich der Gegendruck in der externen Ablaufleitung ändert, wirkt sich dies direkt auf den Druck des Drucköls aus, das das Kegelventil drückt, was zu einer Druckänderung und damit zu einer Änderung des nachgeschalteten Betriebsdrucks des Druckminderventils führt.

Das in Abbildung 17 gezeigte Fehlerphänomen im System wird durch eine Inspektion analysiert und wird durch eine Änderung des Gegendrucks im externen Ablassölkreislauf des Druckminderventils verursacht.

It is easy to see that the electro-hydraulic reversing valves 5 and 6 in the system is changing in the process of reversing the flow and pressure of the return oil in the control oil circuit. The oil in the external drainage circuit of the pressure-reducing valve is also fluctuating, and the two streams of oil merge to produce unstable backpressure.

After debugging, when the electro-hydraulic reversing valves 5 and 6 act at the same time, the pressure gauge 10 reads 1.5 MPa. This is because the electro-hydraulic reversing valve is under the action of a high-pressure control fluid, the instantaneous flow is larger, and in the case of a longer drain pipe, higher backpressure is generated, the backpressure increases. So that the main valve opening of the pressure reducing valve increases, and the local pressure at the valve opening decreases, so the working pressure of the pressure reducing valve increases.

Um diesen Fehler zu beheben, sollten die Ablassleitung des Druckminderers und die elektrohydraulischen Umschaltventile 5 und 6 getrennt wieder an den Öltank angeschlossen werden, damit die Abflussleitung des Druckminderers gleichmäßig und störungsfrei zum Öltank zurückfließen kann und Schwankung, und der stromabwärtige Druck bleibt beim regulierten Druckwert stabil.

Diese obige Analyse zeigt, dass wir während des Entwurfs und der Installation des Systems beim Verständnis der Arbeitsleistung der Komponenten sorgfältig prüfen sollten, ob sich die Komponenten gegenseitig stören.