Temps de lecture estimé : 8 minutes
Hydraulic Circuit using a pressure-reducing valve Figure 15 allows a cylinder or stroke in the circuit to operate at a low relief valve set pressure. A pressure-reducing valve with a check valve is designed so that when the piston returns, the oil flow passes through the check valve without passing through the pressure-reducing element. Hydraulic Circuit
1. La conception du circuit de réduction de pression pour faire attention au problème
- Leakage problem of pilot operated pressure reducing Hydraulic Circuit
Be aware of the pilot-operated pressure reducing valve leakage than other control valves. The leakage of this valve can be as much as 1L / min or more. As long as the valve is in working condition, the leakage is always present. In the choice of hydraulic pump capacity, take this into full consideration. It should note that the minimum adjustment pressure of the pressure-reducing valve should ensure that the difference between the primary and the secondary is 0.31MPa. Hydraulic Circuit
- Problème d'instabilité de pression secondaire
The damping hole of the main spool of the pressure reducing valve is blocked so that the oil exported from the pressure reducing valve cannot flow smoothly into the capacitive cavity between the main valve and the pilot valve. And the pilot valve also reduces the control role of the secondary pressure exported from the pressure reducing valve, resulting in unstable secondary pressure. Hydraulic Circuit
2. Decompression Hydraulic Circuit component setting problem
As shown in Figure 16, the pressure in the branch circuit cylinder 2 after the pressure-reducing valve 3 is lower than the fluid pressure in the master cylinder 1 branch circuit, which is called a pressure reducing circuit. The problems of this circuit are as follows. Hydraulic Circuit
- When cylinder 2 is stopped for a long time, the secondary pressure after pressure reducing valve 3 gradually increases. This is because when cylinder 2 is stopped for a long time, a small amount of oil is discharged through the pilot valve through the spool gap to keep the valve in working condition. Due to the leakage in the valve, the flow through the pilot valve increases, and the secondary pressure (outlet pressure) of the pressure-reducing valve increases. To prevent this failure, you can add the oil circuit shown in the dashed line in the pressure reducing circuit, and install a safety valve at b to ensure that the pressure reducing valve outlet pressure does not exceed its adjustment Hydraulic Circuit.
- The speed adjustment of the hydraulic cylinder in the pressure reducing circuit is not working or the speed is not stable. As shown in Figure 16, this problem occurs when the leakage of pressure-reducing valve 3 (the fluid flowing back to the tank from the pressure-reducing valve drain port) is large. The solution is to change the throttle valve from the position in the figure to connected in series at an after the pressure reducing valve, to avoid the effect of pressure reducing valve leakage on the speed of cylinder 2. Hydraulic Circuit
3. Pression de service instable du circuit réducteur de pression
In the system shown in Figure 17, the hydraulic pump is quantitative, and the hydraulic cylinders 7 and 8 in the main oil circuit are controlled by two-position four-way electro-hydraulic reversing valves 5 and 6 respectively to control the direction of motion, and the control fluid of the electro-hydraulic reversing valves comes from main oil Hydraulic Circuit.
Le circuit de réduction de pression est connecté en parallèle avec le circuit d'huile principal et est dépressurisé par le réducteur de pression 3. L'électrovanne à quatre voies à deux positions contrôle le sens de déplacement du vérin hydraulique 9.
The electro-hydraulic reversing valve controls the return line of the oil circuit and the external drain of the pressure reducing valve. The oil circuit merges and return to the tank, and the operating pressure of the system is regulated by the relief valve2. Hydraulic Circuit
The main oil circuit in the system works normally, but in the pressure reducing circuit, the pressure downstream of the pressure reducing valve fluctuates greatly, so that the working pressure of hydraulic cylinder 9 cannot be stabilized at the regulated pressure value of 1MPa. Hydraulic Circuit
In the pressure reducing circuit, the downstream pressure of the pressure reducing valve, the working pressure of the pressure reducing circuit, occurs in large fluctuations is a frequent failure phenomenon, the main reasons for which are the following. Hydraulic Circuit
- The prerequisite for a pressure reducing valve to be able to stabilise the pressure downstream of the valve at the regulated value is that the upstream pressure of the pressure reducing valve should be higher than the downstream pressure, otherwise the pressure downstream of the pressure reducing valve cannot be stabilised. Main hydraulic circuit working pressure change significantly. Hydraulic Circuit
It will have a larger impact if the minimum pressure value changes lower than the downstream pressure of the pressure-reducing valve, this is because when the upstream pressure of the pressure reducing valve is increase, the downstream pressure may have to be increase instantaneously, but through the regulating action of the pressure reducing valve it will quickly return to the regulating valve. Conversely, when the upstream pressure of the pressure-reducing valve reduces, the downstream pressure of the pressure-reducing valve should reduce instantaneously, and the pressure-reducing valve will quickly adjust so that the downstream pressure rises to the regulated value. Hydraulic Circuit
Si la pression amont fluctue et que sa pression minimale est inférieure à la valeur fixe de la pression aval, la pression aval doit être réduite en conséquence et ne peut pas se stabiliser à la valeur de pression régulée.
Par conséquent, dans les changements de charge de l'actionneur du circuit d'huile principal dans les conditions de fonctionnement, lorsque la pression de service minimale est inférieure à la pression en aval, la conception du circuit doit prendre les mesures nécessaires, telles que l'ajout d'un clapet anti-retour, l'ajout d'un accumulateur entre le clapet anti-retour et réducteur de pression, etc., afin d'éviter que la pression en amont ne passe en dessous de la pression en aval.
- La charge sur l'actionneur est instable. Dans le circuit réducteur de pression, la pression en aval n'est stable que grâce à l'effet régulateur du détendeur. Lorsque l'actionneur a une charge suffisante, la pression en aval doit toujours suivre la loi objective, c'est-à-dire que la pression doit être déterminée par la charge. Aucune pression ne peut se former sans charge, et la pression est plus faible avec une faible charge. Si le circuit de réduction de pression, la pression après le réducteur de pression est réglée dans la condition de charge à un certain moment, mais dans le processus de fonctionnement du circuit de réduction de pression, lorsque la charge est réduite, la pression en aval du réducteur de pression doit réduire jusqu'à zéro. Lorsque la charge augmente à nouveau, la pression en aval du détendeur augmente, et lorsque la pression augmente avec la charge jusqu'à la pression de régulation du détendeur, la pression n'augmente pas avec la charge mais reste à la pression de régulation valeur du réducteur de pression.
Par conséquent, dans des conditions de charge variables, la valeur de pression en aval du détendeur varie, et cette variation ne peut être qu'inférieure à la valeur de régulation du détendeur, mais pas supérieure à la valeur de régulation.
- Il y a une contre-pression dans la conduite de vidange externe. La conduite de commande du détendeur est une conduite de vidange externe. le fluide de commande pousse la vanne conique ouverte puis retourne au réservoir séparément. Si la ligne de vidange externe a une contre-pression qui change, cela affecte directement la pression de l'huile sous pression poussant la vanne conique, provoquant un changement de pression et donc un changement de la pression de fonctionnement en aval du détendeur.
Le phénomène de défaut dans le système illustré à la figure 17 est analysé par inspection et est causé par un changement de contre-pression dans le circuit d'huile de vidange externe du détendeur.
It is easy to see that the electro-hydraulic reversing valves 5 and 6 in the system is changing in the process of reversing the flow and pressure of the return oil in the control oil circuit. The oil in the external drainage circuit of the pressure-reducing valve is also fluctuating, and the two streams of oil merge to produce unstable backpressure.
After debugging, when the electro-hydraulic reversing valves 5 and 6 act at the same time, the pressure gauge 10 reads 1.5 MPa. This is because the electro-hydraulic reversing valve is under the action of a high-pressure control fluid, the instantaneous flow is larger, and in the case of a longer drain pipe, higher backpressure is generated, the backpressure increases. So that the main valve opening of the pressure reducing valve increases, and the local pressure at the valve opening decreases, so the working pressure of the pressure reducing valve increases.
Pour éliminer ce défaut, la conduite de vidange du réducteur de pression et la vanne d'inversion électrohydraulique 5 et 6 doivent être reconnectées au réservoir d'huile séparément, de sorte que la conduite de vidange du réducteur de pression puisse refluer vers le réservoir d'huile régulièrement sans interférence et fluctuation, et la pression en aval sera stable à la valeur de pression régulée.
Cette analyse ci-dessus montre que lors de la conception et de l'installation du système, tout en comprenant les performances de fonctionnement des composants, nous devons examiner attentivement si les composants interfèrent les uns avec les autres.
Salut, avez-vous une seule presse hydraulique, merci?